TPI J3475A1 3470 3-Phase Fan Forced Standard Ceiling Heater, 17000 Btu/hr Capacity, 208 VAC, 5 kW Power Rating

Pricing Notice
Due to evolving trade policies, product prices may be subject to change. For details, please refer to our Terms of Sale. We remain committed to offering competitive pricing and exceptional service.
Terms of SaleHave a Question About a Product?
Our team is here to answer all your questions and provide the detailed information and support you need to make product decisions.
Contact UsTPI J3475A1 3470 3-Phase Fan Forced Standard Ceiling Heater, 17000 Btu/hr Capacity, 208 VAC, 5 kW Power Rating
ManufacturerTPI
Part #633439843
MFG #J3475A1
UPC #686334398435
TPI Ceiling Heater, 3-Phase Fan Forced Standard, Series: 3470, 17000 Btu/hr, 208 VAC, 13.9 A, 5 kW, 425 cfm, 1300 rpm, 37 deg F, Ceiling/Surface Mount, 12 ft Mounting Height, Steel, White, Powder Coated, 16-3/4 in W x 8-9/16 in D x 16-3/4 in H
$2,060.03
 / EAKnowledgeable Product TeamBenefit from our experienced team, ready to assist you with expert product knowledge and ensure a seamless shopping experience.
- Manufacturer Name:Â TPI CorporationAmperage Rating:Â 13.9 ACapacity:Â 17000 Btu/hrColor:Â WhiteCountry of Origin:Â USDimensions:Â 16-3/4 in W x 8-9/16 in D x 16-3/4 in HFinish:Â Powder CoatedFlow Rate:Â 425 cfmManufacturer Name:Â TPI CorporationMaterial:Â SteelMounting Height:Â 12 ftMounting Type:Â Ceiling/SurfacePower Rating:Â 5 kWSeries:Â 3470Speed:Â 1300 rpmTemperature Rating:Â 37 deg FType:Â 3-Phase Fan Forced StandardVoltage Rating:Â 208 VAC
- The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade
- Motor shall be permanent lubricated, unit bearing, totally enclosed shaded pole type with impedance protection
- Motors shall operate at no more than 1300 rpm and shall be same voltage as the heater
- Heaters shall have a rating of 600 cfm at 1000 fpm with a maximum temperature rise of 44 deg F and 63.9 DB RE 10^12 W
- Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins
- Each sheathed element shall consist of helically coiled nickel-chromium alloy resistant wire completely embedded in and surrounded by magnesium oxide, enclosed and wedged into corrosion resistant steel sheaths
- Elements shall have 2 in cold conductor pins extending into sheath and shall have a density of no more than 60 W/in
- Heaters shall be equipped with a "manual reset" thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded
- For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset
- Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted
- Throw designed for 8 to 12 ft ceilings
- UT1001 low voltage recommended remote thermostats
- ARRA Compliant|Buy American Act Compliant|cETLus Listed|PROP65: This product can expose you to chemicals including nickel which is known to the State of California to cause cancer|and chromium|which is known to the State of California to cause birth defects and/or reproductive harm. For more information go to www.P65Warnings.cs.gov
- Indoor-Commercial and Industrial Applications
- Manufacturer Name:Â TPI CorporationAmperage Rating:Â 13.9 ACapacity:Â 17000 Btu/hrColor:Â WhiteCountry of Origin:Â USDimensions:Â 16-3/4 in W x 8-9/16 in D x 16-3/4 in HFinish:Â Powder CoatedFlow Rate:Â 425 cfmManufacturer Name:Â TPI CorporationMaterial:Â SteelMounting Height:Â 12 ftMounting Type:Â Ceiling/SurfacePower Rating:Â 5 kWSeries:Â 3470Speed:Â 1300 rpmTemperature Rating:Â 37 deg FType:Â 3-Phase Fan Forced StandardVoltage Rating:Â 208 VAC
- The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade
- Motor shall be permanent lubricated, unit bearing, totally enclosed shaded pole type with impedance protection
- Motors shall operate at no more than 1300 rpm and shall be same voltage as the heater
- Heaters shall have a rating of 600 cfm at 1000 fpm with a maximum temperature rise of 44 deg F and 63.9 DB RE 10^12 W
- Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins
- Each sheathed element shall consist of helically coiled nickel-chromium alloy resistant wire completely embedded in and surrounded by magnesium oxide, enclosed and wedged into corrosion resistant steel sheaths
- Elements shall have 2 in cold conductor pins extending into sheath and shall have a density of no more than 60 W/in
- Heaters shall be equipped with a "manual reset" thermal overload which disconnects elements and motor in the event normal operating temperatures are exceeded
- For safety, if opened due to abnormal temperature, thermal overload shall remain open until manually reset
- Automatic reset thermal overloads which allow the element to continue to cycle under abnormal conditions will not be accepted
- Throw designed for 8 to 12 ft ceilings
- UT1001 low voltage recommended remote thermostats
- ARRA Compliant|Buy American Act Compliant|cETLus Listed|PROP65: This product can expose you to chemicals including nickel which is known to the State of California to cause cancer|and chromium|which is known to the State of California to cause birth defects and/or reproductive harm. For more information go to www.P65Warnings.cs.gov
- Indoor-Commercial and Industrial Applications
Pricing Notice
Due to evolving trade policies, product prices may be subject to change. For details, please refer to our Terms of Sale. We remain committed to offering competitive pricing and exceptional service.
Terms of SaleHave a Question About a Product?
Our team is here to answer all your questions and provide the detailed information and support you need to make product decisions.
Contact UsTPI CorporationTPI J3475A1 3470 3-Phase Fan Forced Standard Ceiling Heater, 17000 Btu/hr Capacity, 208 VAC, 5 kW Power Rating
Part #:633439843
MFG #:J3475A1$2,060.03
 / EA